Tu Navegador esta des-actualizado, para que el sitio
funcione correctamente porfavor:

Actualiza tu navegador

×

BENEFITS

Benefits
Reduced installation costs, faster and easier to install
Benefits
Size ranges from 1/2“ to 30“ for PVC and CPVC PIPES
Benefits
Keeps fluid temperature stable
Benefits
With less temperature variations, energy consumption is decreased.
Benefits
Our pipes and fittings ensure that you will have a reliable, safe and easy to install fluid conduction system.
Benefits
Sturdy construction prevents impact damage.
Benefits
Prevents Fluid Condensation.
Benefits
Maximum insulation coefficient available in the market.
Benefits
UV light resistant, perfect for outdoor installation.
Benefits
Designed for hot/cold water systems.
Benefits
Performs to the highest expectations even under poor soil conditions and regardless of poor water quality.

INCOTHERM SYSTEM

INCOTHERM is designed to be quickly installed without the need of additional insulation foams that only raise the cost and delay your project. INCOTHERM is compliant with the following standards:
TEST DESCRIPTION TEST STANDARD
Density NMX-C-126-1982
Thermal Conductivity NMX-C-181-1984
Water vapor transmission rate NMX-C-210-1984
Humidity absorption NMX-C-228-1984
All testing performed on our products were as defined by the Mexican Norm NOM-018-ENER-1997 by the polystyrene and derivates laboratory, certified by EMA.

PIR/PUR INSULATION

Material: Espuma de poliisocianurato (PIR)
Dimensional Stability: -20°C /150 °C (-4 °F/302 °F)
Thermic Conductivity: K= 0.13 btu-in/hr-ft2- °F
Density: 75 Kg/m3 / 90% to 95% closed cells
Thermal Resistance: -

Material: Polyurethane Rigid Foam (PUR)
Dimensional Stability: -30°C to 90 °C
Thermic Conductivity: K= 0.14 btu-in/hr-ft2- °F
Density: 65 Kg/m3 / 90% closed cells
Thermal Resistance: R= 1.300 Kxm2/W

DISTRICT COOLING & DISTRICT HEATING

INCOTHERM is the best option for urban water supply networks, it offers unmatched temperature conservation for either hot or cold water. INCOTHERM constantly provides its products to important urban projects across the world, where the full advantages of our products are taken advantage of.

FACTOR K

The K factor of insulation represents the material’s thermal conductivity or ability to conduct heat. Usually, insulation materials have a K Factor of less than one. The lower the K factor, the better the insulation.

INCOTHERM products have a K factor of 22.5 mw/mk

THERMAL PROPERTIES

RIGID POLYURETHANE FOAM VS OTHER INSULATION PRODUCTS COMPARISON:

PRE-INSULATED PIPE
PVC CED 40

MATERIAL THERMAL CONDUCTIVITY
COEFFICIENT
R FACTOR
(Thickness 1)
RIGID POLYURETHANE FOAM .14 - 17 BTU-IN/HR-FT2 ºF THERMAL CONDUCTIVITY EFFICIENCY % 1.300 kxm2/w R FACTOR EFFICIENCY %”
Polystyrene Foam .20 - .22 btu-in/hr-ft2* ºF Incotherm 30% + efficient 0.881 kxm2/w Incotherm 32% + efficient
Fiberglass .23 - .25 btu-in/hr-ft2- ºF Incotherm 39% + efficient 0.765 kxm2/w Incotherm 41% + efficient
Polyethylene Flexible Foam .25 - .27 btu-in/hr-ft2- ºF Incotherm 44% + efficient 0.705 kxm2/w Incotherm 42% + efficient
Cellular Glass .31 - .33 btu-in/hr-ft2- ºF Incotherm 54% + efficient 0.568 kxm2/w Incotherm 56% + efficient
* The lower the coefficient of conduction, the lower the heat loss in the system.
A higher thermal resistance 'R' better insulation

Pipe Mechanical Protection (External Protective Jacket)

INCOTHERM offers 3 different options to protect the polyurethane foam from damage caused by exposure. PVC, Corrugated Polyethylene Jacket (PAD) or Smooth Polyethylene Jacket (PE) are the options**. The protective jackets are recommended based on the needs of the project.
PROTECTIVE JACKET
SANITARY PVC
3” & 4”
Manufacturing Standard NMX-E-199/1

Impact Resistance 6 - 10 kgf/cm2

Self Extinguishable
PROTECTIVE JACKET
Pvc c-3.5
6”, 8”, 10” & 12”
Manufacturing Standard NMX-E-215/1 & NMX-E-215/2

Volumetric Weight/ Resistance 2.000 kg/m3

Self Extinguishable
PROTECTIVE JACKET
Pvc c-5.0
14” & 24”
Manufacturing Standard NMX-E-143-1997-SCFI

Impact Resistance 3.6 kg/m2

Self Extinguishable
CORRUGATED POLYETHYLENE
PROTECTIVE JACKET
Manufacturing Standard NOM-001-CAN-1995

Pipe Hardness 35 DUT

Standard Specifications 3 -10 M 252-02

Standard Specifications 10 -60 M 294-03
SMOOTH POLYETHYLENE
PROTECTIVE JACKET
Outdoor Storage Stability Standard ASTM D2513

UV Resistant

SERVICE PIPES

SERVICE PIPE MATERIAL COMPARISON

PVC SCH 40 INSULATED VS

STEEL

Weight (e.g. 6” pipe v_109 227.29 kg
Length 6 meters per section 6.1 to 6.2 per section (length varies)
Pressure (Kg/cm2) v_115 v_116
Diameter ½” up to 24” 6” to 24”
Standards ASTM D-17 84, ASTM D-1785 & NSF-PW API 5L GRADE B, ASTM A53 (NMX B-177)
Price 40% to 60% more economical 40% to 60% More Expensive
Coupling Gluing Specialized Machinery, Tools and Equipment Required
Handling & Installation Quick, Easy & Reliable Long Duration Because of Required Machinery
Delivery Time Immediate (Depending on Location) 1 or 2 Weeks (depending on location)
Handling & Unloading Hand, Crane or Forklift Crane or Forklift
Additional Insulation None Requires Additional Insulation
Corrosive Damage Does Not Corrode Corrodes
Product Service Life 30 to 50 years 10 to 15 Years